Laboratory and Process Analyzers
Sediments: Particulate Contamination • Sediment in Crude and Fuel Oils by Extraction • Total Sediment Tester
Particulate Contamination
ASTM D5452
Particulate Contamination in Aviation Fuels
This test method covers the gravimetric determination by filtration of particulate contaminant in a sample of aviation turbine fuel delivered to a laboratory.
LT/PC-155000/M
Manual apparatus for Particulate Contamination in Aviation Fuels by Laboratory Filtration - ASTM D5452
- Aluminium structure with anti-vibrating feet according to ASTM D5452.
- 5 litres stainless steel sample tank with drainage tap.
- Metallic funnel with filter support and base for fine closing of the membrane.
- 5 litres graduated cylindrical vacuum bottles for receive sample.
- Grounding system and vacuum connection tube included.
- Include: 100 pcs. of 0.8 micron membrane filters 47 mm diameter made of cellulose acetate.
Weight
Dimensions
- Length 62 cm
- Width 36 cm
- Height 89 cm
Accessories
3794: Diaphragm Vacuum Pump
For U.S. Air Force T.O. 42B-1-1 Jet Fuels Filter Test Time
- 100% oil-free transfer and maintenance-free.
- Pure transfer, evacuation and compression.
- Highly compatible with vapours and condensation.
- Chemically-resistant.
- Therefore, suitable for highly aggressive or corrosive gases and vapours.
- Environmentally friendly
- Delivery (l/min): 30
- Ultimate vacuum (mbar abs.): 100
- Operating pressure (bar g): 0.5
- Connectors for tube (mm): ID 10
- Power Supply: 230 Vac 50 Hz - IP20
- Weight: kg. 3.95
- Dimensions: length 36,1 cm, height 14,1 cm, width 10,2 cm
3012: Digital Stopwatch
1000015: Analytical Balance
- Capacity: 220 g
- Linearity: ±0.2 mg
- Response time: 4/6 sec.
- Calibration: internal
- Readability: 0.1 mg
- Repeatability: ±0.05 mg
- Pan diameter: 80 mm
- Functions
- LCD display with small decimal digits
- Membrane keyboard, water proof and solvent resistant, easy to use with TARE, ON/OFF, PRINT and MENU
- Indication of the reached stable weight
- Bar-graph indicator of dosage and remaining capacity of the balance
- Parameters configurable by menu: reading in g (grams), lb (pound), oz (ounce), ct (carats), pcs (pieces), % (percentage)
- Technical Characteristics
- Full scale automatic calibration with internal and/or external mass
- Weighing underneath the balance
- Selectable response time: "fast/slow"
- Data output: RS232 I/O adjustable
- Operating temperature: 18° ÷ 35°C
- Power supply: 100 ÷ 240 VAC
- Power consumption: 200 mA
- Dimensions: width 21,6 cm, depth 38 cm, height 36 cm
- Weighing chamber dimensions: width 18 cm, depth 17 cm, height 24 cm
- Net weight: 7 kg
- Power supply: 230/115 Vac 50 Hz
1000462: Laboratory solvent dispenser
- Wash capacity up to 1 lt.
- Filter container made in stainless steel diameter 25 mm
- Filter 0.45 µm, 25 mm diameter (P/n 5237), pack of 100 pcs.
- Borosilicated glass flask
- PTFE High quality seal
5237: Omnipore PTFE filters
- 25 mm diameter
- 0.45 µm
- pack of 100 pcs.
LT/DO-248000/N-20: Mini-oven
- 20 liters capacity
- Natural convection
- For temperature from: +5 ambient up to +200°C
- Power supply 220 Vac 50/60 Hz
3794
1000015
1000462
LT/DO-248000/N-20
Spare Parts
- 7101: membrane filters 0.8 micron, pack of 100 pcs.
- 7164: rubber stopper, pack of 2 pcs. and tube for connection
- 7166: grounding system
- 1286: vacuum bottle 5 lt. capacity
- 2168: 5 lt filling container made in stainless steel with stopper for spillage
- 5499: stainless steel forceps for manage the test strips
- 5500: metallic filter funnel supported by a base with support for closing of the tightness membrane, ASTM D5452
Linetronic Technologies SA
Via Onorio Longhi 2 • 6864 Arzo • Mendrisio • Switzerland
tel. +41 91 630 07 03 • fax +41 91 630 07 19