Laboratory and Process Analyzers
Automatic Analysers → NewLab Range • OilLab Range • Thermofat • OnLine Range
Filterability of Lubricating Oils • Ring and Ball • Foaming Tester • Oxidation Stability • Evaporation Bath • RPVOT (570) • RPVOT (571) • Noack • Air Release • Pensky Martens • Leonardo Pensky Martens • Golleo Abel+Pensky • Aniline Point • Penetration • R.E.C.C. • Abel • Cleveland • Tag • Tag - 6901 • Reid Vapour Pressure • Ductilometer • Herschel Emulsifying • Saybolt Viscometer • Distillation
OilLab 880
Saybolt Viscometer
ASTM D88
ASTM D7496
ASTM E102
IP 55
FTM 791-0304
JIS K 2207
Subject
ASTM D88 Saybolt Viscosity: covers the measurement of viscosities of petroleum products at temperature between 21° and 99°C (70° ÷ 210°F)
ASTM D7496: This test method utilizes the Saybolt Furol viscometer to measure the consistency of emulsified asphalt. It is applicable to all the emulsified asphalts specified in Specifications D977 and D2397.
ASTM E 102 Saybolt Viscosity: covers the measurement of viscosities of petroleum products at temperature between 121° and 232°C (250° ÷ 450°F)
Principle of detection
The sample is heated and mantained stable at test temperature.
Once the analisys start the valve is opened and a real time CCD camera will observe the flow of the sample until reach the level mark and close the valve. The time and relevant viscosity index (SUS and/or SFS) are automatically calculated.
Measuring Temperature Devices
- Bath temperature: PT100 sensor stainless and steel
Detection system
- Integrate CMOS sensor high definition
- Integrate LED backlight
Heater
Safety Devices
- Safety thermostat over-temperature cut-out
Software Features
- User friendly interface
- All analytical parameters recorded
- Customizable analysis parameters and methods
- Customizable results report
- Printable graphs and results
- Orifices calibration procedure with reference sample
- Centering procedure of the level mark of the receiver flask
- Automatic open/close valves
- Automatic viscosity calculation
- Audible chimie alarm for over-temperature
- Selectable temperature displaying: °C / °F
The software includes:
Analysis Menu
- Automatic execution of the analysis in accordance to the selected procedure (Standard method as per ASTM / IP / ISO / EN / DIN… norms of reference)
- Display in real time of all the analysis parameters and status
- Fields for introduction of operator and product name
- Audible alarm and displayed messages at the end of the analysis and in case of errors and/or malfunctions
Diagnostic Menu
- Direct access to all analog, digital, inputs and outputs
- Selectable value displaying: °C / Volt
Calibration Menu
- Up to 100 calibration points (standard with 5 and dynamic with up to 100 points)
- Last calibration date referred to each single probe displayed and relevant data printable
- Display of calibration diagram
- Comparative with reference thermometer
- Selection calibration due date
Data Utilities
- Archive viewer for files recall
- All analysis stored in Excel® compatible format
Analysis storage
- Storage capacity for more than 65.000 analysis
- Export of test results files in the most common formats Excel and PDF
- Reading interval of PT100 sample from 0 to 450 °C with resolution 0.1 °C
Integrated Touch Screen Panel PC
- TFT/LCD 8.4"
- Resolution 1024 × 768, 16.2 M colours
- 1 × USB ports for connection to an external printer
Electrical Supply
- 220V ± 15% / 50 to 60 Hz
- 115V ± 15% / 60 Hz
Ambient Temperature
Weight
Dimensions
- width: 43 cm
- depth: 38 cm
- height: 60 cm
Accessories
- LAB-100-161: filter funnel with stainless steel wire mesh
- LAB-100-162: Saybolt flask 60 ml
- LAB-100-163: thermometer support
- LAB-100-164: withdrawal tube
- LAB-100-167: movement ring ASTM E 102
- LAB-100-168: suction pipette
Spare Parts
- LAB-100-161: filter funnel with stainless steel wire mesh
- LAB-100-162: Saybolt flask
- LAB-100-164: withdrawal tube
- LAB-100-165: universal orifice
- LAB-100-166: furol orifice
- LAB-100-168: suction pipette
- LAB-100-371: silicone oil 25 litres
- LAB-140-001/A: PT100 probe
- LAB-11-0012: heater
Linetronic Technologies SA
Via Onorio Longhi 2 • 6864 Arzo • Mendrisio • Switzerland
tel. +41 91 630 07 03 • fax +41 91 630 07 19